To replace the 54 x 1500W Metal Halide Fixtures a photometric study was done and showed that using 96 x 600W our Luminaires would illuminate the baseball field and increase the light levels immensely, all while reducing energy.

96pcs-600W-1 96pcs-600w-Baseball-field-lighting 96pcs-600w-Baseball-field-lighting-1

The Baseball Field used 2 different Beam spreads to get uniform illumination levels of the field. 64 Luminaires used narrow beam 15D Lens, 32 Luminaires used 30D Lens. Our Luminaires have a high color rendition showing true colors: with a CRI >82. Our Proprietary Glare-Free Illumination (UGR <21) makes for no uncomfortable sensation or visual discomfort for the players and spectators. Our Luminaire’s proprietary thermal management system allows for continuous airflow keeping the Luminaire cool in the harsh environment. Our Proprietary Design offers Uniform and Constant Light Levels throughout the Life of the Luminaire, with ignorable Lumen Depreciation. Additionally, with a rated Luminaire life of up to 80,000 hours, the Luminaires will last over 5 times longer than the old Metal Halide Lamps. Ballasts were also eliminated from the circuit, additionally reducing maintenance costs and energy consumption.

Savings:

Prior Traditional Energy Consumption:

54X1500W=81000W

Current Energy Consumption:

96X600W=57600W

Please Clip The Product To Know More Specification.

500W-600W-A

Conclusion

The Baseball Field now has an LED Solution that will last for years allowing them to spend their time, money, and resources on more productive projects instead of changing failed lamps and ballasts.

Welcome to contact us by [email protected] to get your Lighting Plan – For Free

 

RELATED PROJECTS